bosch solution 6000 user manual

File Name:bosch solution 6000 user manual.pdf
Size:3250 KB
Type:PDF, ePub, eBook, fb2, mobi, txt, doc, rtf, djvu
Category:Book
Uploaded4 May 2019, 21:32 PM
InterfaceEnglish
Rating4.6/5 from 551 votes
StatusAVAILABLE
Last checked3 Minutes ago!

bosch solution 6000 user manual

We have 3 Bosch SOLUTION 6000 manuals available for free PDF download: Installation Manual, Owner's Manual, Quick User Manual. Made In Australia TELEPERMIT Bosch Security Systems Pty Ltd reserves the right to make changes to features and specifications at any time TELEPERMIT without prior notification in the interest of ongoing product development and improvement. See below for list if modules which can be added to the control panel. Module Space Occupied Solution 6000 Control Panel 2 Module Spaces CM704B Zone Expander 1 Module Space CM705B Universal Expander. Always check the orientation of the terminal block with the PCB markings before connecting it to the PCB.These terminals are used to connect the telephone line from the street. These terminals are used to connect the premises telephones.Bosch Security Systems 07-14 BLCC610I. In smaller installations where no LAN modules have been installed there is no need to fit the termination resistor on the control panel. The LAN must be terminated correctly for proper operation.Zone Input Terminals Voice Module Connection Socket (Optional) Telephone Line Connection Socket (RJ12 6P4C) Telephone Line Connection Terminals Figure 24: Terminal Descriptions Bosch Security Systems 07-14 BLCC610I. The time is set using a 24 hour clock.The default key is single use only. Refer to the CM255B instructions for additional information.To erase Ur1 John Smith press OK.The keypad will only list users that have an RF Keyfob assigned.The keypad will display the current PIN retry count.Armed Part 2 - when the area has been turned Part 2 On.This provides silent feedback to the user that the signal has been received.The keypad will display the current exit time set for the area selected.Zones set as Burglary Instant 1 have Exit Delay and sent to the central station receiver.They will trigger an alarm regardless of Note whether or not the system or area is in the Armed, Part Armed or Disarmed state.In version 2.14, this has been corrected.http://www.sonimages.de/upload/bosch-plena-matrix-manual.xml

Badging requires that you present your token 3 times in succession within 5 seconds to arm the system.Setting this option causes the system to trigger an 2) The keypad will display the zone to be tested.The output will reset when the system or becomes unsealed.In version 2.14, this has been fixed.Open Pulsing Low Output is normally open circuit and will pulse LOW when the event occurs. The output will reset when the output event restores. Use the Time Parameter to set the pulse duration.The output will only reset One Shot Mode when the time specified in the Time Parameter expires.The keypad will display the following during the strobe test.Outputs 1 to 4 are High current digital outputs and Output 5 is the onboard relay output. Outputs 9 to 40 are only available if the optional Output Relay Expander Boards (CM710B) are fitted. See MENU 5-1-6 and MENU 5-1-7 to program the Call Forward ON and Call Forward OFF number Note sequence.Currently it is not possible to reset the programmable messages back Note factory default settings.This option sets the panel to send a line fail report when it detects a telco line fail condition.See Note Section 3 - Wiring Diagrams for more information.Simply add these numbers before the Call Back number.Each example below shows the log on step for clarity.In displayed. this situration the LAN would need to be unsecured and then perform a LAN scan or power cycle.This signal may not be provided by all compatible RF Receivers.The Solution 6000 is only configured to work with one panel. System Trbl. RF receiver is missing or disconnected.If either of these codes are left as default then the keypad will display the system trouble Default PIN.Security for defaulting. A charge applies for this service. Keep in mind that this page is secure and confidential. How do I do this. For business clients, the request must come on a company letterhead or from a company email address.http://majcentrum.com/user_uploads/file/bosch-plena-bgm-paging-system-manual.xml

The procedure for changing the user code can be found in your user manual or on our alarm support page. Please also advise Austech Surveillance that you will be vacating so we know to expect a call from the new owners. The correct procedure for doing so can be found in your user manual or in the user manual on our alarm system support page. If you would prefer, you can have a qualified technician attend to your code change by contacting us on 1300 737 225 Once mains power is restored, the system will recharge the battery. You should test your system at least once per month, however the interval for regular servicing varies from system to system. Please refer to the Risk Assessment included in your Austech Surveillance Welcome Pack for specific information regarding your systems required servicing schedule. Key features include: The 144 fully programmable intrusion zones can support sensors fitted to doors and windows, motion sensors and smoke detectors. When events are detected, the Solution 6000 can sound sirens, transmit events to your monitoring service provider and activate lights,This way you can monitor the movements of your staff daily if required. Completely customisable. These amazing sensors are virtually FALSE ALARM PROOF The noise sound from these sirens make it almost impossible to stay inside your home while they are running. These are a very effective visual deterrent to would-be thieves Have the Melbourne Alarms system installed and try it out for a full year. If you don’t believe it has performed the way I have promised, let me know. Our unique RISK-FREE 30 day Money Back Guarantee. It could be after you leave home in the morning. Or it could happen when you return home. Garage Mate solves that problem. It will send you an alert if the door is still open after a pre-set time. You can close the door right from your smartphone or from your web browser.

View details View details View details The elegant codepad blends in with an decor and the built-in back light makes the display easy to read even in low light conditions. It has a built-in panic button and the ability to arm living areas at night for your peace of mind while sleeping. View details Icon code pad is supplied with this package - call the office for latest pricing on other options. We'll answer you as soon as possible.Now I feel better with the safety of Good system. Many thanks” He was professional and efficient. The result was very satisfactory Happy customer. Thanks Thanks for helping us out All our Technicians are qualified with Cable and Security Licences and each technician has at least 20 years’ experience in this field. Please phone us for any urgent orders or to check stock levels. Pickups - We are still allowing pickups from our store. Please order and pay online. We are no longer accepting face-to-face payments.If you don't have a phone line, or are using NBN or VoiP the Bosch 6000-GSM is the perfect Solution for you. The system provides full text driven SMS reporting functions straight to your mobile, and with the IOS app, you can control your security system from your phone. Turn the alarm on and off, open doors and control outputs. Optional GSM module with SIM card. Colour coded, illuminated keys allow for easy identification and operation in all ambient light conditions and provide a positive feel to the user. Red and green indicators provide easy identification of armed and disarmed modes and the in-built sounder provides audible feedback via polyphonic like signalling tones during system operation. Zones may be programmed individually to monitor all types of security alarms, fire alarms and supervision devices. The new LAN readers include egress and lock control built in, which reduces cost and simplifies installation. Each user can be given a unique PIN code, RF key fob, Proximity token, and fingerprint credential if required.

The Solution 6000 supports variable length PIN codes up to 8 digits. Should a burglary or other incident occur, the loss is not just the items destroyed or stolen - it's the loss of comfort and security that your workplace once provided. The Solution 6000 from Bosch Security Systems provides you with an expandable solution that can be tailored to fit your business perfectly. This integrated access control and alarm system combines an impressive array of alarm functionality with the access control capabilities you've always needed. With future focused technology and the ability to adapt to your changing needs and work environment, Bosch have eliminated the complexities of finding the right security solution for your business. Look no further than the Solution 6000 to unlock the access and alarm solution that your business has been looking for. It is capable of providing simple cost effective solutions for mid-sized businesses, yet is powerful enough to handle 144 zones (detention devices), and even up to 16 access doors when fully expeanded for large applications. With programmable authority levels, you determine which functions each staff member can perform: simple operations such as turning the system on and off, or accessing restricted areas. Customised security has never been so simple. Your child ca have their own code which triggers an SMS to your mobile when they come home from school. Talk to Cheap Alarm Parts for more information on Access Control.Up to 16 time zones can be set up, with each containing up to 4 time periods.Up to 1000 individual system users have the choice of arming and disarming using a unique PIN code (up to 8 digits long), a wireless remote, proximity card or token, biometric fingerprint or by using the Auto Arm function. The flexibility of the Auto Arm Function enables you to program your system to automatically arm at pre-defined times.

Programmed schedules can also extend to control the locking of gates or turning building lights on and off, providing a complete business solution. Colour coded, illuminated keys make it easy to operate your security system, day or night. Red and green indicators provide easy identification of Armed and Disarmed modes, and the built-in sounder provides audible feedback when operating the system. These small remote controls allow you to arm and disarm your business premises by simply pressing one button.The 6000 fully programmable intrusion zones can support sensors fitted to doors and windows, motion sensors and smoke detectors. When events are detected, the Solution 6000 can sound sirens, transmit events to your monitoring service provider and activate lights, providing security you can rely on 24 hours a day. This way you can monitor the movements of your staff daily if required. It provides the flexibility for your staff to arm and disarm the areas that they have been given access to, without affecting other areas of your business. For your convenience the Solution 6000 can be configured to use a single key pad for all areas, or individual key pads for each area. The benefits begin with the installation stage itself, which is straightforward, inexpensive and, if you wish, wireless. Complex security installations are now a thing of the past. In this way, devices can be placed up to 1.2km from the control panel itself, making the system extremely flexible when dealing with large buildings or multiple buildings, like separate warehouses. The chime mode feature is extremely useful for monitoring driveways and fire doors too. This fully automatic self testing unit allows you to forget the system is there, while knowing you are still protected. Whether your office space is large or small, Bosch Security has a solution for you. Please don't copy them and put them on your website. Seriously. It makes us cranky.

Although Telstra and Vodafone have already started phasing out parts of their 3G networks for older devices, at this stage, no one has confirmed any specifics around when 3G will be switched off entirely. Telstra will continue to operate 3G services on its 850MHz spectrum until June 2024. Optus has yet to provide any timeline for when it intends to shutdown its 3G network. Unlike Telstra and Vodafone, it isn't currently phasing out any of its 3G network frequencies. Once the 3G network is turned off entirely, the communicator in this product will need to be upgraded to 4G. As of July 2020, when this paragraph was written, there were no 4G units available for the product, but they are in development and will be available once testing has been completed by the manufactures. If you continue to browse and use this website, you are agreeing to comply with and be bound by the following terms and conditions of use, which together with our privacy policy govern Cheap Alarm Parts’s relationship with you in relation to this website. If you disagree with any part of these terms and conditions, please do not use our website. It is subject to change without notice. You acknowledge that such information and materials may contain inaccuracies or errors and we expressly exclude liability for any such inaccuracies or errors to the fullest extent permitted by law. We reserve the right to not accept your offer and fully refund you any amounts we have taken as a deposit for your order. In the event of this happening we apologise for the inconvenience and where possible will substitute a similar product of equal or better quality. We will notify you if the product is not yet available. However, specification and particulars in relation to the products referred to are subject to change without prior notice. Some photographs contain samples which are representative only. Some tems may vary in colour and look.

We reserve the right to correct such errors and apologise if they might have affected you. This includes holding, cancelling or fully refunding your order before dispatch. Transactions are incomplete until the product or service has been dispatched or received by the consumer. It shall be your own responsibility to ensure that any products, services or information available through this website meet your specific requirements. This material includes, but is not limited to, the design, layout, look, appearance and graphics. Reproduction is prohibited other than in accordance with the copyright notice, which forms part of these terms and conditions. These links are provided for your convenience to provide further information. They do not signify that we endorse the website(s). We have no responsibility for the content of the linked website(s). We are committed to ensuring that your privacy is protected. Should we ask you to provide certain information by which you can be identified when using this website, then you can be assured that it will only be used in accordance with this privacy statement. We may change this policy from time to time by updating this page. You should check this page from time to time to ensure that you are happy with any changes. We may contact you by email, phone, fax or mail. We may use the information to customise the website according to your interests. In order to prevent unauthorised access or disclosure, we have put in place suitable physical, electronic and managerial procedures to safeguard and secure the information we collect online. Once you agree, the file is added and the cookie helps analyse web traffic or lets you know when you visit a particular site. Cookies allow web applications to respond to you as an individual. The web application can tailor its operations to your needs, likes and dislikes by gathering and remembering information about your preferences.

This helps us analyse data about webpage traffic and improve our website in order to tailor it to customer needs. We only use this information for statistical analysis purposes and then the data is removed from the system. Overall, cookies help us provide you with a better website by enabling us to monitor which pages you find useful and which you do not. A cookie in no way gives us access to your computer or any information about you, other than the data you choose to share with us. You can choose to accept or decline cookies. Most web browsers automatically accept cookies, but you can usually modify your browser setting to decline cookies if you prefer. This may prevent you from taking full advantage of the website. However, once you have used these links to leave our site, you should note that we do not have any control over that other website. Therefore, we cannot be responsible for the protection and privacy of any information which you provide whilst visiting such sites and such sites are not governed by this privacy statement. You should exercise caution and look at the privacy statement applicable to the website in question. We may use your personal information to send you promotional information about third parties which we think you may find interesting if you tell us that you wish this to happen. If you believe that any information we are holding on you is incorrect or incomplete, please write to or email us as soon as possible at the above address. We will promptly correct any information found to be incorrect. The Graphic User Interface incorporates a text driven menu. Colour coded, illuminated keys allow for easy identification and operation in all ambient light conditions and provide a positive feel to the user. Red and green indicators provide easy identification of Armed and Disarmed modes and the in-built sounder provides audible feedback via polyphonic like signalling tones during system operation.

The sounder emits a siren sound during alarm condition providing early warning and the volume level is individually programmable for each key pad connected to the system. Zones may be programmed individually to monitor all types of security alarms, fire alarms and supervision devices. The panel supports multi-vendor wireless devices allowing you to select the most appropriate products for each installation Access control is no longer reserved only for larger more expensive systems. Proximity technology from Bosch provides an affordable and effective solution for up to 16 access doors. The new LAN readers include egress and lock control built in, which reduces cost and simplifies installation Panels. The Solution control panel is factory default only for one area. As soon as you turn an area on, exit time will start. Exit time allows you to exit the premises without sounding an alarm. Your security company programs the length of exit delay time. You should leave now. If your Solution control panel detects a faulted zone, you should return it to normal, or bypass the zone.The Solution control panel is factory default only for one area. Part On and Part 2 On turns on only part of the area, leaving the rest of the area turned off. The master user can program which zones are monitored when a user turns an area Part 2 On. You should leave all zones that are active before exit delay time expires. Leaving active zones after exit delay expires causes an alarm event. Use Part On or Part 2 On only when you want part of an area turned on. You should leave now. If your system has a faulted zone, you should return it to normal, or bypass the faulted zone.Opening a designated door (e.g. front door) will start entry time. During entry time, the keypad will emit a pulsing tone “beep” to remind you to turn the system off.The keypad will scroll all alarms on the keypad display for visual feedback.

If you enter your PIN before the system dials your security company, the alarm report is cancelled (if programmed). This is called alarm memory. The auto-on pre-alert time sounds the keypad buzzer to warn you that the system will automatically turn All On, Part On or Part 2 On. Therefore the system will automatically turn All On at 7:00pm. To arm the system call the number which the panel is connected to and when the panel answer you will here 3 beeps in accending frequency if the panel is in the disarmed condition. You will hear 3 beeps in decending order when the panel arms. A003 Administration Dept The keypad display below shows the area icons 1 through to 8. You should leave all areas now. However, this menu requires at least one area that has a keypad assigned to it to be disarmed before you can access this command. When bypassing zones, it disables the ability for a zone to detect intrusion and sound an alarm. Any 24-Hr fire or 24- Hr non fire zones will need to be manually un-bypassed. To un-bypass, press OFF. To bypass, press ON. This can be useful when you need to monitor the front or back entrance to the premises. Only keypads programmed to sound the chime tone will be heard when a zone programmed for chime is faulted. A002 Sales Dept A003 Administration Dept Each keypad will need to have their volume adjusted separately. Each keypad can have their display adjusted separately. Please wait To successfully walk test each zone, you must open and close each zone. The keypad will display a list of areas that are available to walk test zones. A zone that has been successfully tested will no longer scroll on the keypad display. When all zones have been tested, the keypad will display: The keypad will display a list of zones that are available to be tested via walk test. The keypad will display the zone to be tested. The test will last for 5 seconds. The test will last for 5 seconds. Please wait..

The Solution 64 will automatically test the battery once per day and every time the system is armed. Press OK to continue Please Call for Service. Press OK to continue Some trouble events require you to drill down and non-system trouble that are curent within the Solution control panel. If there is not a general power outagein your area then you should contact your security company. You should contact your security company as the battery may need replacing. You should contact your security company. This situation may preven certain parts of your system from working correctly. You should contact your security company. You should contact your security company. You should contact your security company. You should contact your security company. These codes should be changed immediately to prevent a security risk. Inspect and contact your security company if necessary. You should contact your security company. You should contact your security company. You should contact your security company. You should contact your security company. The keypad will now prompt you to enter your new PIN again. A group of characters is assigned to each of the numeric keys on the keypad. Pressing the same numeric key again will toggle to the next character assigned to the key (eg. Once the correct character is display use the arrow keys to move to the next letter of the word you are entering. The key assignments are identical to those found on most fixed and mobile phones. Pressing the same numeric key repeatedly will step you through the available characters assigned to the key. The text key layout is the same as most phones. Refer to the table below for detailed character information. It is recommended that you write down the old PIN and the new one before you begin. Once the change is complete you should destroy the written copy. The new PIN must have the same number of digits as the old PIN. The default PIN for User 1 (Master user) is 2580.

The keypad will display a list of available users that you can change their PIN. A Master user can only program a new PIN for those users that have been assigned to the same area(s) as the Master user. The default PIN for User 1 (Master user) is 2580. A list of users will display on the keypad. If an error tone sounds, try a different new PIN. A Master user cannot delete their own PIN. The keypad will list all users that you can delete. A list of users will display on the keypad. Once the token is presented the keypad we beep and return to the menu. A Master user cannot delete their own PIN. Only tokens that have been assigned to the same area(s) as the Master user can be identified. The system will prompt you to present the token to the keypad. 2. Once the token is presented the system will display the owner of the token. The RF Keyfob must be compatible with the RF Receiver that has been installed by the security company. A list of users will display on the keypad. A list of users will display on the keypad. A maximum of 16 characters can be entered. A list of users will display on the keypad. Each user can be assigned to one or multiple areas. The master user is restricted and can only assign another user to any one or multiple areas that the master user has been assigned to. At factory default, each user is assigned to operate Area 1. To do this you need to create a time group, then assign one or more schedules to the time group to specify the access period, day of the week and holidays. To now restrict the user, they must belong also to the same timer group. This now restricts the user from accessing the system outside the nominated times and days within the schedules linked to the timer group. If a user tries to operate the system outside their assigned timer group periods then access will be denied. Timer Groups can be used to restrict User access to be within specific times defined by schedules. Each User can only be assigned to one Timer Group.

Setting this option to 0 will give the User 24 hour access to the system. These outputs can be used to control door strikes, gates or roller doors etc. SA61998 SA No. ISL 149773 ACT No. 17501831 QLD No. 40506. Please refer to the Bosch Solution 6000 user guide for more information or the My Alarm Pty Ltd website. There is also a YouTube video showing some basic information on how to set up the My Alarm SMS Control App. YouTube Video: How it works: By having the Bosch GSM SMS module installed, onto your alarm panel, and set up correctly, as well as a active SIM card with reception and credit, the alarm panel is able to, not only send SMS's to several mobile numbers to alert about alarms or faults ect, but it can also receive SMS's which can be used to control the alarm, for example arm the alarm, from your mobile phone. This ability to be remotely controlled relies on SMS messages. It is not a permanent or live connection. In order to control the alarm via SMS, the SMS message needs to contain a string of details, for example user code, what control function and what device to control, ie arm area 1, the alarm system needs the SMS messages to be written in a very specific format, ie '1234, Area, 1, ON, Confirm' if it is written incorrectly, the alarm will ignore it, there is a large list of SMS message strings however this can be very hard on you, the end user, to type these out correctly, and to remember them, that's were the My Alarm SMS Control App comes in, it is simply a program used to create templates (pre programmed string of information) that you can easily click and send to the alarm at any time. Notes: In order to be able to control the alarm via SMS, your mobile number must be programmed into the alarm as a allowed number, this is to prevent unauthorised people to control your alarm, even if they have the user code. Document: BJR-B6000-SMSCA V02 Updated: 19 JAN 2015 Created by BJR Security.

This is the PURPLE app as shown above and is made by My Alarm Pty Ltd.This should be the opening screen shoot Document: BJR-B6000-SMSCA V02 Updated: 19 JAN 2015 Created by BJR Security. A site is the alarm you will be controlling, it is set up with the SIM cards phone number and your alarm PIN code. If you only have one alarm then you will only need one site, however if you have several Bosch Solution 6000 alarms with GSM modules that you wish to control, ie home and work ect, you may have two or more sites setup. Enter a name for this site, for example 'Home Alarm' Enter the GSM phone number, this is the phone number of the SIM card installed in the alarm system, for example Enter your PIN number you use for the alarm, for example 1234 Document: BJR-B6000-SMSCA V02 Updated: 19 JAN 2015 Created by BJR Security. Once you have selected an icon it will return to the previous screen, click Save. If you wish to create another site (for another alarm) click 'Add' Once all sites have been created, click 'Back' You now need to set up templates. A template is set of instructions you wish to send to the alarm via SMS A template is required for each set of instructions you may wish to use, for example one template would have to be set up to arm the alarm, another to disarm the alarm, another to check the status (check if the alarm is armed or disarmed) and another to turn an output on ect. To create a template, click 'ADD SMS Template' Document: BJR-B6000-SMSCA V02 Updated: 19 JAN 2015 Created by BJR Security. For most applications, all zones (sensors) will be allocated to Area 1, so you only need to select '1', however for larger installations ie commercial there may be 2 or more area, ie warehouse, office ect. For this example we are only setting this up for Area '1' Click on the number '1' so it becomes black, leave the others off.